Jun. 24, 2024
Want more information on Rockwool panels for insulating shipping containers? Feel free to contact us.
Spray foam insulation extruding from a duct.Spray foam (expanding foam in the UK) is a chemical product created by two materials, isocyanate and polyol resin, which react when mixed with each other and expand up to 30-60 times its liquid volume after it is sprayed in place. This expansion makes it useful as a specialty packing material which forms to the shape of the product being packaged and produces a high thermal insulating value with virtually no air infiltration.
History
[
edit
]
Otto Bayer () is credited with the invention of polyurethane in . He succeeded in synthesizing polyurethane foam by exploring his basic idea that mixing small volumes of chemical substances could create dry foam materials.[1]
Polyurethane was further developed for different applications, ranging from shoe soles and cushions to industrial uses. In the s rigid foam was applied to airplanes,[2] and in polyurethane began being used as building insulation.[3]
Properties
[
edit
]
Thermal resistance
[
edit
]
R-value is the term given to thermal resistance to heat flow. The higher the R-value of an insulation product, the more effective the insulation properties. Spray polyurethane foam comes in a range of densities and cell structure. Low density foams are referred to as open cell SPF while higher density foams are referred to as closed cell foam. 1.8-2 pound polyurethane foam has the highest R-value of readily available spray foam insulation used in homes and buildings.[4]
Polyurethane is a closed-cell foam insulation material that initially contains a low-conductivity gas in its cells.[5] As a result of the high thermal resistance of the gas, spray polyurethane insulation typically has an initial R-value around R-3.4 to R-6.7 per inch.[5] In comparison, glass wool typically has an R-Value of only R-3 to R-4 per inch.[6]
Foam insulation blocks all three forms of heat transfer:
Applications
[
edit
]
Packaging applications
[
edit
]
Spray foam is a very specialized packing material, often required for use in shipping valuable fragile items. Engineered packaging principles are designed to protect sculptures, vases, large fossils, lamp bases, busts, computers, furniture, chandeliers and other objects of unusual shape. By virtue of the liquid foam expanding by up to 30-60 times the volume of its liquid state, it efficiently protects almost any size, form and weight.
The custom fit of the molds, top and bottom, securely and uniformly cushions the object. There are many types of alternative materials that can be used to handle more specific needs.
Building applications
[
edit
]
Walltite Insulation foam being sprayed Closed cell spray foam being applied by trained installer.Spray foam insulation or spray polyurethane foam (SPF) is an alternative to traditional building insulation such as fiberglass. A two-component mixture composed of isocyanate and polyol resin comes together at the tip of a gun, and forms an expanding foam that is sprayed onto roof tiles, concrete slabs, into wall cavities, or through holes drilled into a cavity of a finished wall.
"Spray foam" is also an informal term used to refer to various plastic foam materials that are used in building construction to provide thermal insulation and minimize air infiltration. Polyurethane and polyisocyanurate are two types of foam used in this application.
Types
[
edit
]
Spray polyurethane foam (SPF) insulation can be categorized into two different types: light-density open-cell spray foam insulation and medium-density closed-cell spray foam insulation. Both types of SPF are thermoset cellular plastics comprising millions of small cells.[7]
Open cell spray polyurethane foam insulation being applied in wall cavities.Open cell insulation can be crushed in your hand and has a lower insulation value. Closed cell is rigid to the touch and each air cell is completely sealed. While closed cell foam has a higher R-value, it is more costly to buy.[8]
Medium-density closed-cell spray foam (ccSPF)
Medium-density closed-cell foam insulation is often referred to as two pound (2 lb) foam. It is a rigid insulating material with a Long Term Thermal Resistance (LTTR) R-value that ranges between 5.1 and 6 per inch[9] When the required minimum thickness of 50 mm is installed, ccSPF is both a vapour barrier and an air barrier.
In Canada, the National Building Code references two standards that apply to the manufacturing and installation of ccSPF: the CAN/ULC S705.1 Material Standard and the CAN/ULC S705.2 National Application Standard. The installation standard requires that all installers of ccSPF in Canada be licensed and carry a photo ID card.[10]
Typically the foam's natural colour is yellow, however in Canada all ccSPF that have CCMC listings are required to have a unique colour for field identification.[11]
Light-density open-cell spray foam (ocSPF)
Light-density open-cell SPF is commonly known as half-pound foam. It is a semi-rigid material with a sponge-like appearance that expands during installation and creates small, open cells that are filled with carbon dioxide. Due to its ability to expand during the application process, it fills cracks, crevices and voids and adheres to irregular surfaces or substrates to form an air sealing insulation.[12]
While the R value will vary, most ocSPF products have an R value of around 3.8 per inch. Unlike medium-density closed-cell SPF, thinner layers of ocSPF are not particularly effective as vapour barrier because the air infiltrates through the open cell structure. However, when installed at 5.5 inches or more, ocSPF does act as an air barrier. It is often used for interior walls because it provides sound reduction by blocking and absorbing air leakage. It is usually only recommended for indoor applications.
Application methods
[
edit
]
Asia
[
edit
]
A type of use quite familiar in South East Asian countries is applying the foam by spraying it against the bottom of roof tiles under high pressure with a spray gun. A hard but flexible layer of rigid foam is then created and seals all the tiles to each other and to the steel structure.
This spraying method, especially very popular in Thailand, is used not only against heavy leaks but helps also as insulation against the enormous heat the roofs constantly face.
Contact us to discuss your requirements of Fast Installation Fire Resistance Wall Panel. Our experienced sales team can help you identify the options that best suit your needs.
This tropical heat causes the steel substructure that supports many roofs in that part of the world, to continuously expand and contract, changing slightly the position of the tiles resting on top of them. This displacement eventually creates small openings between the tiles and the substructure, through which rainwater can seep, creating leaks that can damage the plastered ceilings, electric wiring, and other components of the building supporting the roof.
Europe
[
edit
]
Some 150,000 properties have been treated with polyurethane foam insulation in the UK. There are systems which have British Board of Agreement approval for use in existing and new build applications and can show compliance to Building Regulations. However, if applied incorrectly or in damp spaces, spray foam insulation can trap moisture and destroy the roof.[13] As a result, very few mortgage lenders in the UK will offer a loan to buy or to refinance any home that has any spray foam insulation, especially the closed-cell type.[13]
North America
[
edit
]
The Canadian National Building Code references the CAN/ULC S705.2 National Application Standard which must be followed during all installations of 2lb medium density closed cell polyurethane foam. Every installer of CAN/ULC-S705.1 compliant medium density, spray applied foam must be licensed in order to spray foam and hold valid photo ID issued by their Quality Assurance Program (QAP) provider showing their license is in good standing.
The United States has adapted to using sprayfoam insulation and a new technology called Wall Injection to retrofit existing wall construction by drilling small holes between wall studs in the structures framing and filling the void with a less aggressive expanding water-based foam. This allows existing home and business owners to conserve energy by creating a thermal envelope in their existing structure.
Benefits
[
edit
]
Spray foam insulation, like other insulation, saves on energy costs and lowers utility bills. Studies by the US Department of Energy show that 40% of a home's energy is lost as the result of air infiltration through walls, windows and doorways. Buildings treated with spray foam insulation insulate as much as 50% better than traditional insulation products.
Insulation properly deployed can be part of a system designed to protect against moisture, which provides the benefit of reducing the chance of harmful mold, mildew and rotting of wood.
In addition to building temperature and moisture control, spray foam insulation is often used to reduce noise. Foam insulation serves as a barrier to airborne sounds, and reduces airborne sound transfer through a building's roof, floor and walls compared an uninsulated structure.[14]
In the United States, homes treated with spray foam insulation often qualify for state and federal tax deductions.[15]
Insulation of all types stops a good deal of energy loss. Some types including spray foams also seal air leaks. Insulation can also save energy in hot climates by reducing air conditioning use.
Blowing agent history and climate impact
[
edit
]
Most closed-cell spray foam was formed using hydrofluorocarbon (HFC) blowing agents that have high global warming potential, partially or completely offsetting the climate benefits of the energy savings they can offer. Global treaties such as the Montreal Protocol, Kyoto Protocol, Kigali Amendment, and Paris Climate Agreement all include requirements for phasing out and substituting less environmentally friendly blowing agents. In the United States, a rule under the United States Environmental Protection Agency's (EPA) Significant New Alternatives Policy (SNAP) programme regulated the phase-out of certain high-GWP blowing agents and the transition to lower-GWP goods. The rule increased the alternatives list and restricted the use of high-GWP hydrofluorocarbons (HFCs) in foam blowing.
A few spray foam suppliers have started supplying spray foam blown with hydrofluoroolefin (HFO) blowing agents without this problem as of early .[16] In a worldwide patent was awarded to Foam Supplies Incorporated for a new generation eco-friendly foam blowing agent that is free of Chlorofluorocarbons (CFCs), Hydrochlorofluorocarbons (HCFCs), and Hydrofluorocarbons (HFCs) called Ecomate®. This is based on naturally occurring methyl methanoate.
Health effects
[
edit
]
Spray foam insulation is typically non-toxic only after it has cured. While curing, spray foam emits a gas that causes blurred vision and trouble breathing. Using full face and respiratory protection while applying the product is recommended.
Isocyanates are powerful irritants to the eyes and gastrointestinal as well as the respiratory tracts. Direct skin contact with isocyanates can also cause marked inflammation. Some people say that their eyes feel like they have sand in them at the onset of problems. Some break out in a rash on their arms, chest, and neck.
Overexposure to isocyanates can sensitize workers, making them subject to asthma attacks if they are exposed again. Respiratory irritation may progress to a chemical bronchitis. Additional exposures can make the onset easier with less isocyanate necessary to start the attack.
Sporadic cases of hypersensitivity pneumonitis (HP) have also been reported in workers exposed to isocyanates. The symptoms may seem like the flu, with fever, muscle aches, and headaches. Other symptoms may include a dry cough, chest tightness, and difficult breathing. Individuals with chronic HP often experience progressively more difficult breathing, fatigue, and weight loss. Individuals with acute HP typically develop symptoms 46 hours after exposure.[4]
Curing times of new generation spray foam insulation are very short. Once cured the foam is completely inert and non toxic.
See also
[
edit
]
References
[
edit
]
At Stackhouse, we understand the importance of staying underbudget on your container home build. If spray foam insulation seems out of the realm of possibility for your budget, there are a number of other viable alternatives that will still get the job done.
Similar to spray foam in composition, expanded foam insulation is basically just spray foam sold in pre-fabricated sheets.
Typically sold as large, pre-sized sheets and panels, pre-manufactured expanded foam is usually found in lengths that match the heights of a standard 8 foot ceiling. Also commonly-available in a 48 length, these sheets of expanded foam are often sold with mylar backing adhered to one side to maximize their effectiveness.
Expanded foam is easy to cut with a straight razor and can typically be laid like drywall in the gaps between the metal studs along a container wall. Similar to drywall, the gaps between sheets of expanded foam are typically sealed with a mylar tape that lessens the possibility of air and energy escaping after installation.
Unfortunately, this type of container insulation is prone to deteriorating R-value over time and a small user error in installation can drastically reduce its ability to insulate. Expanded foam board is also unable to create a weatherproof seal like closed cell spray foam, as the seams between pieces are much more likely to let water in under certain circumstances.
Regardless of its shortcomings, expanded foam insulation is the highest R-value container home insulation alternative available outside of spray foam and is definitely worthy of consideration for a budget build.
The most commonly-available varieties of expanded foam insulation are as follows:
Lower- R-Value open cell foam with air filling open spaces. Open Cell Polyurethane Foam is less dense than closed celled varieties and exhibits a spongier feel
Closed Cell Polyurethane is the closest you can get to the insulating effectiveness of a spray foam in a pre-fabricated form. Its R-value is higher due to the addition of a blowing agent that replaces the air in the open cell foam with another gas with better heat conduction efficiency.
Similar in composition to Polyurethane Foam but manufactured with a different chemical reaction that makes it more rigid and thermally-resistant
Sheets of small plastic beads that have been fused together to form a uniform, rectangular piece.
Melted plastic material thats been molded into rectangular sheets.
If youre uninterested in insulating your container home with foam, there are still a number of other options available for you to consider.
Are you interested in learning more about fireproof roofing sheets? Contact us today to secure an expert consultation!
If you are interested in sending in a Guest Blogger Submission,welcome to write for us!
All Comments ( 0 )