The role of new staplers in reducing the incidence of air leak

Author: Daisy

May. 20, 2024

The role of new staplers in reducing the incidence of air leak

You will get efficient and thoughtful service from Ezisurg.

Associated Data

Supplementary Materials

The article’s supplementary files as

jtd-15-02-893-prf.pdf

(63K)

DOI: 

10.21037/jtd-22-192

jtd-15-02-893-coif.pdf

(87K)

DOI: 

10.21037/jtd-22-192

Abstract

Surgical staplers play an important role in the contemporary minimally invasive thoracic surgery including resection of lung tissue. However, staple line failure resulting in postoperative air leaks is a common complication after lung surgery, that if persist more than five days are defined as prolonged air leaks (PALs). PALs are associated with increased length of stay, patient morbidity and mortality, and hospital costs. To reduce the incidence of PALs, stapler devices underwent in the last years ongoing development aimed at improving device-to-tissue interaction. This clinical practice review explores the most important aspects of the evolution of surgical staplers, based on the review of the available literature. Modern staple cartridges entail small bumps to engage tissue and minimize tissue movement during compression and firing. Staplers with graduated staple heights are advocated to generate less stress on tissue during compression and clamping, thus affording greater perfusion into the staple line. However, air leaks may occur from an appropriate staple line with complete pleural coverage and perfusion due to enlarged staple canals after lung inflation, particularly in case of emphysema. To buttress staple line, thus prevent air leaks in high-risk patients, several types of tissue coverage (bovine pericardium, polytetrafluoroethylene, knitted calcium alginate, bioabsorbable polyglycolic acid) have been successfully developed in the last years. Finally, the most advanced stapler technology is represented by the new energy powered staplers, able to eliminate the manual firing force, monitor tissue compression during firing, and making automatic adjustments to optimize the staple line.

Keywords:

Lung surgery, pulmonary lobectomy, air leakage, linear stapler

Introduction

With the advent of modern video-assisted thoracoscopic surgery (VATS), mechanical stapling of lung tissue has become essential for both anatomical and atypical lung resections. Since the first successful use of stapler devices for lung surgery in the USSR in the 1950s as well in the USA in the 1960s, endoscopic instruments have been developed for minimally invasive surgery allowing precise, safe, and time saving transection and simultaneous sealing of lung tissue (1).

The failure of staple lines resulting in postoperative air leaks is a frequent complication of lung surgery, with persistent leaks lasting over five days termed as prolonged air leaks (PALs), which have a reported incidence of 8%-26% (2,3). Past studies have linked PALs with increased patient morbidity, mortality, extended hospital stays, and higher healthcare costs (3,4).

Maintaining the integrity of staple lines is vital for creating a completely sealed transection line and preserving perfusion of tissue margins. This has been a major focus of ongoing advancements by manufacturers of surgical staplers (5). Recent innovations have aimed at enhancing device-to-tissue interaction by optimizing key components of stapler devices:

  • ❖ Surface of cartridge and length of staples,

  • ❖ Buttress of staple lines with non-absorbable or absorbable material, and

  • ❖ Mechanism of firing staples and cutting the tissue.

This Clinical Practice Review provides an overview of these features in new staplers aimed at reducing the incidence of air leaks, based on a comprehensive review of the available literature.

Evolution of staple and cartridge conformation

Traditional cartridges were flat-faced with single-height staples. To improve the fixation of the device to the tissues and—therefore—its stability during stapling, manufactures have developed different solutions with focus either on the length of staples or the surface of the cartridge.

The Tri-Staple™ reload (Medtronic, Minneapolis, MN) has a stepped cartridge face that delivers graduated compression and three rows of varied height staples. That design is advocated to generate less stress on tissue during compression and clamping ( ) (6).

Open in a separate window

The Echelon™ stapler reloads (Ethicon Inc., Cincinnati, OH) feature Gripping Surface Technology (GST), which entails small bumps extending from the driver wells such that the cartridge face is not flat. These bumps are intended to engage tissue and minimize distal and lateral tissue movement during stapler compression and firing ( ) (7).

Open in a separate window

To date, there is limited published information on the above-mentioned technologies. Imhoff and Monnet compared two graduated compression staples (Tri-Staple™, Covidien) and standard staples (Endo GIA™, Covidien) for lung biopsy in dogs. In this ex vivo experimental study graduated staples leaked at significantly lower airway pressures than standard staples, so the authors concluded that they may not be suitable for canine lung biopsy (8). On the other hand, a single paper reports the application of Tri-Staple™ on human lung tissue, with no complications noted in 56 uses for either wedge resection or bronchus closure (9).

In an ex vivo porcine lung model Eckert and coll. investigated differences in air leak occurrence and air leak rates between two different ventilation modalities: positive pressure ventilation (PPV), mimicking intraoperative ventilation, and negative pressure ventilation (NPV), mimicking natural breathing. In addition, they compared the rate of air leaks associated with staple-line configuration with uniform staple heights (UNI) versus graduated staple heights (GRD) under both ventilation modalities. The authors observed an increased occurrence of leaks as well as higher leak rates under NPV than under PPV, and by using graduated staple design than uniform staple design (10).

Another issue is the choice of the appropriate staple height to avoid a mismatch between staple height and tissue thickness, which may result in a leakage due to necrosis or poor apposition. Cartridges are available with different heights of closed, B-shaped staples, varying from 0.75 to 2.3 mm, and are color-coded according to the staple height. However, the staple reload selection is an empiric process based on surgeon’s judgement, because there is no current method providing an objective intraoperative measurement of deflated tissue thickness prior to cartridge selection.

Reinforced stapler cartridges

The role of staplers as a protection against air leak was studied in a meta-analysis by Lu et al., they compared the effect of staplers vs. electrocautery in patients undergoing segmental lung resection. Because of the high risk of leakage through the quite long tissue resection line uncovered by visceral pleura, this group of patients is most likely to suffer PALs. In the series of 385 patients the advantage of the mechanical staplers on reduction of PAL rate was reported with an OR of 3.91 (95% CI: 1.64–9.35; P=0.002) (11).

However, air leak may occur from an appropriate staple line with complete pleuralization either due to tissue ischaemia or enlarged staple canals. The latter mechanism plays an important role in patients with severe emphysema undergoing lung surgery, as reduced thickness of tissue layers in the staple line may offer less resistance against local pressure in the inflated lung, resulting in enlargement of staple canals or small lacerations of the surrounding visceral pleura.

To buttress staple line, thus prevent air leaks in patients with emphysema, several types of tissue coverage have been developed in the last years.

In the literature the most frequently studied covered line is with bovine pericardium. These reinforced staplers have been always compared with sealants regarding the effectiveness on PAL prevention. Buttresses have been shown in randomized trials to decrease the incidence and duration of air leaks, as well as the time chest tube is required in patients with severe emphysema undergoing atypical resection (12). Although the data are not clear for patients with severe emphysema undergoing anatomic lobectomy or segmentectomy, we assume that it is reasonable to use staple-line buttresses in this patient group as well.

Regarding liquid sealants, most studies have reported neither statistically nor clinically significant improvements in hospital stay or time to removal of chest tube. Although one might think it logical that sealants would demonstrate a clearer benefit in patients with substantial emphysema, this may not be the case, and only a single small study (albeit with positive results) has looked at this subgroup of patients (13). Also needed are studies that are large enough for stratification based on the size of the initial intraoperative air leaks, studies that look at prolonged or complicated air leak as an outcome measure, and studies that evaluate PAL-related costs (12).

Are you interested in learning more about surgical stapler price? Contact us today to secure an expert consultation!

Based on the mentioned study on patients undergoing lung volume reduction surgery (LVRS), there is evidence that covered stapler may prevent air leakage through stapler line. The mechanical explanation of the effect of covered staple line was also studied on cadaveric lung models from Murray et al. They confirmed that unreinforced staple lines began to leak air at an airway pressure of 20 mmHg, and >90% leaked at a pressure of 35 mmHg. Both bovine pericardium and expanded polytetrafluoroethylene (ePTFE) used in the study significantly reduced the incidence of air leak at these airway pressures. At higher airway pressures, ePTFE was superior to bovine pericardium (13). Similar results emerged from the study conducted by Downey et al.: on an experimental pig model, they compared reinforcement with four different materials with normal staplers under different pressure up to 75 mmHg. The conclusion was that commercially available reinforcements allow pulmonary staple lines to tolerate higher intrabronchial pressures without developing air leak. In addition, reinforcement with small intestinal submucosa afforded a significant advantage to the other reinforcements in terms of staple line leak rate. The main limitation of this study was that the authors compared in most of cases the staplers outside the physiologically applied pressure during the operation, as the pressure rarely overcome 30 mmHg (14).

The clinical implication of the above-mentioned studies has been confirmed in a randomized clinical trial performed in leading thoracic surgery centres in Europe (Vienna, Zurich, and Essen). The study group concluded that the median duration of air leaks after LVRS was shorter in the buttressed stapler group than in the control group (0 vs. 4 days; P<0.001), with a corresponding shorter median drainage time in this group (5 vs. 7.5 days; P=0.045). Hospital stay was similar in the two groups (median: 9.5 vs. 12.0 days; P=0.14) (15).

The need to reinforce staple line was also confirmed based on the experimental study of Bonnet et al., in which they compared microscopic lung tissue changes of a porcine lung model after lung resection with and without stapler. They concluded that only perfect allocation of the stapler can prevent leakage through the lung parenchyma. This conclusion is quite important in the era of VATS resections, as stapler line allocation may be not always that perfect depending on the different thoracoscopic access (uniportal or multiportal). In order to prevent PALs, their conclusion indirectly stresses the need of staple line reinforcement in selected patients (16).

Different types of reinforcement material are available on the market. The most utilized ones are bovine pericardium (BP) and polytetrafluoroethylene (PTFE) patches, both not resorbable. In their study Vaughn et al. compared the tissue response after reinforcement of the staple line either with the pericardium or PTFE. Based on their experimental dog model they observed that at 30 days, the BP specimens showed chronic inflammatory changes and thin tissue incorporation, whereas the PTFE specimens had no inflammation and was embedded by a thick tissue layer. At 3 and 6 months, the inflammation in the BP specimens had resolved, but tissue incorporation remained minimal, whereas in the PTFE specimens tissue coverage had increased (P<0.0001). No air leaks, staple-line failure, or infections were observed in both study groups. In conclusion, a more favourable tissue response was observed in the group with PTFE patches (17). Further, we could find some anecdotal papers concerning complications after application of bovine pericardium like metalloptysis (18,19).

There are many others reinforcement materials which are under investigation und can represent an alternative to the widely used ones. The most important characteristic of these materials should be easily application, high sealing power, and safety.

In a multicenter study from France the role of knitted calcium alginate (FOREsealTM) sleeves for buttressing the staple line were investigated in different types of resections. Intraoperative air leakage was assessed at a mean ventilatory peak pressure of 30 cmH2O, and rated as grade 1, 2, or 3. Persistent air leakage in the postoperative course, as well as any relevant event, were assessed daily. The study group concluded that FOREsealTM is an ergonomic, safe, and promising new material instead of nonabsorbable materials and xenomaterials for staple-line reinforcement (20).

Contrary to the results of the French Investigation was the conclusion regarding the efficacity of FOREsealTM in a randomized controlled trial conducted by Alifano et al. They have tested the efficacy of the mentioned buttress in preventing PAL in high-risk patients with emphysema undergoing anatomical lung resection (lobectomy or bilobectomy). Based on collected data of 380 randomized patients the authors concluded that buttressing has not advantages over standard fissure separation with linear stapler without reinforcement (21).

Another newly investigated agent for buttressing the staplers is bioabsorbable polyglycolic acid (PGA). Deguchi et al. conducted a propensity score matched analysis on two groups of 125 patients each. They results confirmed that using the stapler with PGA to divide the incomplete interlobar fissure for lobectomy reduced postoperative air leakage and decreased the need for additional intraoperative management using fibrin glue as compared with stapler without reinforcement ( ) (22).

Open in a separate window

In their experimental investigation on a dog model, Hashimoto et al. have compared the efficacy of different stapler line buttressing, also including the combination form FOREsealTM plus PGA. They concluded that this alginate buttress may be more effective for preventing air leakage after lung surgery, because it has both sealant and bolster effects working in conjunction. Interestingly, in their study model the applied pressure for proving air tightness of stapled lung parenchyma was more than 50 mmHg—away from the more physiological pressures applied during intraoperative ventilation (23).

A quite new and scarce investigated material is the small intestinal submucosa (SIS). The report by Downey et al. has shown some advantages over commercially used bovine pericardium as well as PTFE. A possible explanation of his quality was that due to its bioabsorbable profile SIS may be a more suitable material for staple line reinforcement in selected patients requiring nonanatomic lung resection (14).

In conclusion, based on the evidence of the literature the role of the buttressed stapler seems to be important to reduce the rate of postoperative PALs, especially in the group of patients with predictive factors for this economically relevant surgical complication.

The new (energy) powered staplers

The evolution of the minimally invasive thoracic surgery needed the improvement of the stapler design to reduce not only the operation time but also postoperative complications such as PAL. The evolution of surgical staplers has been described previously; nowadays the most advanced stapler technology are the powered staplers. The powered stapling systems offers one-handed, push-button operations, which eliminate the manual firing force and possibly enable more precise resection.

Increased tension to reduce the costs of surgery despite of increasing material costs can be mostly compensated by reducing the length of patient’s hospital stay. That’s why it is important to prove if the newly designed staplers can reduce the overall costs of lung surgery by preventing postoperative complications such PAL.

Based on the analysis of 433 patients with the use of staplers in their VATS lobectomy for lung cancer, Gao et al. confirmed that the use of powered stapler afforded a significantly shorter operation time and postoperative hospital length of stay than using the manual stapler in a multivariable regression analysis adjusted by patient characteristics. However, no other significant differences, including the rates of PAL were observed for other clinical outcomes between the two stapler groups (24).

A confirmation of the above-mentioned results has emerged from the study conducted by Licht et al., who investigated the clinical outcome after VATS using a new surgical stapling device in two different geographic regions (United States and Europe). Ten participating institutions enrolled a total of 226 subjects in this study. Primary endpoints were occurrence and duration of postoperative air leaks, including PALs. Regional differences were observed for cartridge selection relative to tissue type and intraoperative leak

80

0