Marine boilers are one of the most ignored machinery systems on board ships. Often neglected in scheduled maintenance, boilers are usually attended only when malfunction and breakdown occurs. What follows is an expensive and time-consuming repair leading to delay in voyage, stoppage of cargo operations or increase in port stay time.
haoyuefurnace contains other products and information you need, so please check it out.
With rising operational expenses and fuel prices, along with stringent environmental regulations, there is a considerable pressure on professionals to reduce energy consumption and operating costs.
Boiler failure can occur because of a variety of reasons such as oil contamination, overheating, failure of tubes, oil leakage etc. Moreover, corrosion and deposits also greatly impact maintenance expenditures because of problems such as localised overheating of metals, under deposit corrosion, and flow restrictions.
In this four part series, get practical knowledge and helpful tips on carrying out operation and maintenance of boilers on board.
Marine boilers are steam generators where heat resulted from combustion of a fuel, from nuclear reaction or thermal effect of electrical current is transferred to the water which is heated and vaporized.
There are two types of boilers in marine industry:
Water tube boilers are preferred onboard vessels because of multiple advantages compared with fire tube boilers. From all these advantages we can mention:
The steam generating plant consists, generally, of one auxiliary oil-fired boiler and one exhaust gas boiler. On some vessels there will be a composite type boiler which comprises of an oil-fired boiler and exhaust gas boiler integrated within.
In port the steam demand of the vessel is served by the oil-fired boiler, but while at sea the vessels steam demand is met by the exhaust gas boiler. In this case the oil-fired boiler can be left on automatic stand by ready to cut in if the steam pressure drop below a predetermined set point.
The oil-fired auxiliary boiler is of the steel welded, usually vertical, cylindrical design, with a closely spaced tube bank in the upper section. The tube bank rests in the combined steam/water drum which is cylindrical. Steam is generated by the hot gases flowing vertically, horizontally or mixing both ways (depending boiler type) through the tube bank which contains water. Modern marine boilers are oil-fired by a horizontal burner situated in the lower section.
Where necessary, manholes are provided for easy access and inspection. The combined steam/water drum has a feed water internal pipe, surface blow-off internal pipe and water sampling pipe. Insulation is provided on the outer surface of the boiler and the outermost surface is covered with galvanized steel casing.
There are many types of boiler burners available onboard vessels, but the most common ones are Pressure Jet and Rotary Cup types. Apart from these, burners can be of variable orifice pressure jet, spill pressure jet, ultrasonic or steam assisted types.
Rotary cup oil burner type on oil-fired boilerPressure jet type burner on oil-fired boilerThese burners are suitable for HFO (or LSHFO in ECA or SECA areas) with MDO used for the igniter. It is also possible to burn waste oil in the boiler, and usually the boiler control panel has a facility for changing to waste oil operation. In this case MDO is used when flashing-up from cold condition.
When the boiler is started for the first time or after repair and/or prolonged shutdown period, the following procedure generally applies:
In some cases a steam heating or warming through coil is provided in the boiler shell and water in the boiler may be warmed using this coil thus reducing the period of time taken to raise steam pressure by means of the burner. The steam necessary for this operation must be available from the exhaust gas boiler. If the boiler is shut down for a period of only few days it should be maintained in warm condition by means of heating coil.
Boiler control panel provides operation, control and interlock devices required for boiler normal operation. The control panel performs the automatic and manual operation of the boiler and it gives an alarm to warn the operator if an abnormality occurs during operation.
Example of oil-fired boiler control panelIn the same time, the panel tops the boiler in case of an emergency, by immediately shutting down the fuel supply to the boiler burner, if such abnormality deemed to be too serious to continue running the boiler. Normally the control unit is provided with the following safety features:
In case of automatic operation of the boiler, the starting up is quite simple and below procedure generally apply (manufacturer instruction manual must be consulted for specific type of boiler) :
For more information, please visit Composite Boiler Diagram.
The manual operation system allows for firing the boiler, in the event of faults in the automatic sequence control or components of safety monitoring equipment. The procedure for starting the boiler in manual mode is generally as described below (manufacturer instruction manual must be consulted for specific type of boiler):
It is important to remember that during boiler manual operation there is no function of burner sequencing control unit and during burner off periods the flame supervision circuit has a voltage applied in order to carry out the detector and extraneous light test.
It is essential that the boiler is constantly supervised by a competent engineer when operating in manual mode, as in this situations the safety interlocks are reduced to:
Marine boilers are very important and sensitive equipment onboard vessels, therefore special care and attention should be paid. The are some situations when engineers must pay proper attention and they must be properly trained for such.
For example in case of a flame failure, make sure that the oil valve is closed and reduce the air pressure to prevent furnace over cooling (usually these processes are automatic). Purge the furnace before relighting the burner as you must make sure that no remnant fuel is trapped in the furnace as this could lead to a blow back of hot gases. Never attempt to relight the burner from the hot furnace refractory.
Another case can be when boiler trips due an emergency, like Too low water level alarm. In this case shut the steam main valve, feed valve and forced draught fan after purging the furnace. Never attempt to fill the boiler with feed water until the boiler has cooled sufficiently.
When taking a boiler out of service, the wet lay-up method is preferable, because it requires less preparation and the boiler can be returned quickly to service. When is in the cooling down process following shutdown, treatment chemical must be injected using the boiler dosing unit in order to ensure adequate protection of the boiler. Always follow the guidelines chemical supplier as excessive chemical may be more detrimental than insufficient chemical.