Oct. 07, 2024
Sodium hypochlorite generator is a set of low concentration of salt water through the electrified electrode electrochemical reaction after the generation of sodium hypochlorite solution device. Its workflow is:
With competitive price and timely delivery, GIANT ANODE sincerely hope to be your supplier and partner.
1. Sodium hypochlorite generator is a combination of forms, through the measurement of dilute brine added to the electrolysis tank, through the silicon rectifier connected to the yin and yang direct current electrolysis to generate sodium hypochlorite.
2. 1 kg of sodium hypochlorite salt consumption: 4.0-4.2; 4.3-4.5 KW.
Website:
3. in brine solution contains Na+, H- and several other ions, in accordance with the theory of electrolysis, when inserted into the electricity, under a certain voltage, electrolyte solution due to the movement of ions and electrical reactions, conductive, then CL-, OH- and other negative ions to the Yang, while Na+, H+ and other positive ions to the anion to the negative, and in the corresponding electric discharge occurs, so as to carry out the redox reaction, the corresponding substances.
4. saline solution electrolysis process can be expressed in the following reaction equation: NaCl = Na + + Cl-
5. positive electrolysis: H2O = H + OH- 2Cl-2e- Cl2 negative electrolysis: 2H- + 2e- H2
6. in the diaphragm electrolysis device, the electrolyte and electrolysis products of hydrogen in solution to the outside outside outside, the other are in an electrolytic tank, due to the hydrogen outside the escape process of the solution to play a certain amount of stirring, so that the two between the electrolysis of the products of a series of chemical reactions, reaction equations are as follows:
2NaCl+2H2O2NaOH+H2+Cl2 2NaOH+Cl2NaClO+NaCl+H2O
7. In the diaphragm electrolysis of salt water, the total equation of the solution that is listed above the two reaction formulas add up. NaCl + H2O + 2F NaClO + H2 where: F for the Farah electrolysis constant, the value of 26.8 Ampere hours, or 96,487 Coulomb.
Website:
8. Sodium hypochlorite generator consists of electrolysis tank, silicon rectifier electronic control cabinet, salt dissolution tank, cooling system and supporting PUVC piping, valves, water jets, flow meters and other components. Add 3~4 dilute salt solution into the electrolysis tank, connect 12V DC, generate sodium hypochlorite by adjusting the electrolysis current electrolysis, absorb and mix the disinfectant solution by the water jet, or measure the disinfectant solution through the mixer by the metering pump.
The above is the working principle of sodium hypochlorite generator is simple, I hope to help the big, will also be released from time to time the knowledge of sewage treatment equipment maintenance and management, mixing should be big continue to pay attention to us!
Sodium hypochlorite generator is a device used to generate sodium hypochlorite solution, which is commonly used for the disinfection of swimming pools, drinking water and industrial wastewater. Sodium hypochlorite is a strong oxidizing agent with bactericidal, disinfectant and bleaching properties.
www.hsanode.com
The working principle of sodium hypochlorite generator is to produce sodium hypochlorite by electrolyzing salt water.
Specifically, a sodium hypochlorite generator usually consists of an electrolyzer in which an anode and a cathode are inserted. The electrolyzer is filled with brine, usually a sodium chloride (NaCl) solution.
When an electric current is turned on, an electrolytic reaction occurs between the anode and cathode. At the anode, chloride ions (Cl-) are oxidized to chlorine gas (Cl2), while at the cathode, water is reduced to produce hydrogen gas (H2) and hydroxide ions (OH-).
The chlorine gas produced reacts with water to form hypochlorous acid (HClO) and hydrochloric acid (HCl). Hypochlorous acid is the active ingredient of sodium hypochlorite, which has strong oxidizing and bactericidal disinfecting ability.
www.hsanode.com
In order to improve the efficiency of sodium hypochlorite generation, generators usually employ measures such as increasing the area of the electrolyzer, improving electrode materials, and optimizing the concentration and temperature of the electrolyte. In addition, the production and concentration of sodium hypochlorite can be regulated by controlling the current density, electrolysis time and flow of electrolyte.
The generated sodium hypochlorite solution can be transported to the water to be treated for disinfection, sterilization or oxidation through an appropriate piping system.
The operating principle of the sodium hypochlorite generator is based on an electrolytic chemical reaction which, through proper design and operation, can effectively produce sodium hypochlorite solution for water treatment and other related applications. It is important to note that when operating and using the sodium hypochlorite generator, it is important to follow safe operating procedures in order to prevent chlorine leakage and other safety issues. It is also necessary to select the appropriate generator model and operating conditions according to the specific water treatment needs and water quality characteristics.
Are you interested in learning more about electrolytic sodium hypochlorite generator? Contact us today to secure an expert consultation!
www.hsanode.com
Advantages of sodium hypochlorite generator:
1. No need to use dangerous chemicals, such as chlorine, high safety.
2. Sodium hypochlorite generator can produce high concentration of sodium hypochlorite solution with good disinfection effect.
3. Sodium hypochlorite generator also has the advantages of simple operation and easy maintenance.
www.hsanode.com
When using the sodium hypochlorite generator, it is recommended that the equipment be regularly inspected, cleaned, replaced and other maintenance work to effectively extend its service life and improve operational efficiency.
The cleaning steps of sodium hypochlorite generator are as follows:
1. Turn off the generator and cut off the power supply;
2. Remove the electrode and membrane of the generator. 3;
3. soak the electrodes and membranes in clean water and gently brush them with a brush to remove the dirt on the surface;
4. Place the main body of the generator in clean water, add appropriate amount of cleaning agent and soak for 1-2 hours. 5;
5. Rinse the main body of the generator with clean water until it is clean;
6. install the electrode and membrane back into the generator, turn on the power and check whether the equipment is running normally.
When cleaning the sodium hypochlorite generator, you need to pay attention to safety, avoid the use of corrosive cleaning agents, and at the same time, strictly comply with the operating procedures of the equipment to avoid damage to the equipment.
www.hsanode.com
The maintenance and repair of sodium hypochlorite generator should pay attention to the following issues:
1. Regularly check the equipment: regularly check the operating condition of the equipment, check whether the pressure, flow, temperature and other parameters of the equipment are normal, check whether the sealing of the equipment is good, if there is any abnormality, it should be dealt with in time.
2. Regular cleaning of the equipment: the sodium hypochlorite generator will produce some sediments and impurities during operation, which need to be cleaned regularly. When cleaning, you can remove the electrode and membrane, soak it in water, and gently brush it with a brush to remove the surface dirt. At the same time, you can also put the main body of the generator into clean water, add the appropriate amount of cleaning agent, soak for 1-2 hours, and then rinse with clean water.
3. Regular replacement of electrode and membrane: Electrode and membrane are one of the core components of sodium hypochlorite generator, which can affect the performance of the equipment and the quality of output. Generally speaking, the service life of electrode and membrane is 1-2 years, and they need to be replaced regularly.
4. Pay attention to safety: when maintaining and servicing the sodium hypochlorite generator, it is necessary to pay attention to safety, avoiding the use of corrosive cleaning agents, and at the same time, strictly observing the operating procedures of the equipment to avoid damage to the equipment.
:
5. Pay attention to the environmental temperature and humidity: the operating environment temperature and humidity of the sodium hypochlorite generator will also affect the performance of the equipment and the quality of output. Generally speaking, the operating environment temperature of sodium hypochlorite generator should be controlled between 5-40 and the humidity should be controlled below 80%.
6. Regularly add electrolyte: Sodium hypochlorite generator needs to consume electrolyte during operation, which needs to be added regularly. When adding electrolyte, it should be operated according to the instruction manual of the equipment to avoid adding too much or too little.
The above are some of the problems that need to be paid attention to in the maintenance of sodium hypochlorite generator, it is recommended to carry out reasonable maintenance according to the actual situation of the equipment, in order to prolong the service life of the equipment and improve the operational efficiency.
If you want to learn more, please visit our website platinized titanium anode.
If you are interested in sending in a Guest Blogger Submission,welcome to write for us!
All Comments ( 0 )