Why is maintenance free battery vs agm Better?

Author: Ruby

Aug. 13, 2024

Flooded Batteries vs. AGM Batteries: Understanding the ...

When it comes to lead acid batteries, two popular options are flooded (sometimes called conventional) batteries and AGM (Absorbent Glass Mat) batteries. While both serve the purpose of energy storage, they have distinct differences in terms of construction, maintenance, performance, and applications.

CAMEL contains other products and information you need, so please check it out.

In this blog post, we will explore the key differences between flooded batteries and AGM batteries to help you make an informed choice for your specific needs.

What is the difference between flooded batteries and AGM batteries?

Flooded Batteries

Flooded batteries, also known as wet cell batteries, have a traditional design consisting of lead plates submerged in a liquid electrolyte solution. The plates are separated by separators, and the electrolyte level needs to be monitored and periodically topped with distilled water. They typically require regular maintenance to ensure optimal performance and longevity.

Maintenance activities include checking and maintaining proper fluid levels by adding distilled water as needed, monitoring electrolyte-specific gravity, and periodic equalization charging to address electrolyte stratification.

They require a specific charging regimen to maintain optimal performance. The charging rate for flooded batteries is typically expressed as a percentage of the battery&#;s capacity (C-rate). The recommended charging rate for flooded batteries is generally less than 10% of their capacity. For example, a 100Ah flooded battery should be charged at a rate of 10A or less.

Charging at a slower rate helps ensure a complete and thorough charge, allowing the electrolyte to mix properly and minimizing the risk of stratification. To learn more about C-rates visit battery universities&#; article, &#;What is C-rate?&#;.

The bulk charge voltage of a 12V flooded lead-acid battery is typically 14.2 volts. This voltage is commonly used during the bulk charging stage to quickly replenish the battery&#;s charge. During bulk charging, a constant current is applied to the battery to rapidly restore its energy.

The higher voltage helps facilitate the electrochemical reactions within the battery, allowing for efficient charging. However, it&#;s important to note that the specific bulk voltage can vary depending on the battery manufacturer, design, and temperature conditions.

The float charge voltage is typically 13.4 volts. The float voltage is the voltage at which a fully charged battery is maintained during a standby or maintenance mode. During the float charging stage, a lower voltage is applied to the battery compared to the bulk charging stage.

This voltage level is intended to keep the battery at a fully charged state without overcharging or creating excessive gassing. It compensates for the self-discharge of the battery and any small loads connected to it, ensuring that the battery remains ready for use.

AGM Batteries

AGM batteries feature a sealed design with a fiberglass mat soaked in electrolyte. The mat is placed between the lead plates, effectively immobilizing the electrolyte. AGM batteries do not require the addition of water or electrolyte checks, as the design eliminates the need for maintenance associated with fluid levels.

They have a different charging profile compared to flooded batteries. AGM batteries generally have a more controlled charging approach. The recommended charging rate for AGM batteries is typically around 10-25% of their capacity. Their unique glass mat separator design can be charged at higher rates than flooded batteries due to reduced internal resistance and better charge acceptance. The glass mat separator tightly holds the electrolyte in place, preventing spillage and excessive gassing, allowing for faster charging without damaging the battery. For more information on AGM technology visit our blog post, &#;The Complete Guide to AGM Batteries&#;.

The bulk charge voltage of a 12V AGM lead acid battery is typically 14.7 volts, and the float charge is typically 13.8 volts.

When should a flooded or AGM battery be used?

The choice between AGM or flooded batteries should be determined by the intended application, budget, and charging control.

Assess the specific needs of your application. Flooded batteries are the optimal choice for applications where cost is a primary concern, and regular maintenance can be performed. They can handle higher discharge rates and provide a higher surge current than AGM batteries. This makes them suitable for applications that require high-power output, such as automotive starting applications, off-grid renewable energy systems, and heavy-duty industrial equipment.

In comparison, AGM batteries are ideal for sealed and maintenance-free setups. AGM batteries have a lower self-discharge rate than flooded batteries. They can retain their charge for longer periods when not in use, which can be advantageous for applications with infrequent or seasonal use. Additionally, the glass mat separator makes them highly resistant to vibrations and shocks. They are commonly used in applications such as deep-cycle storage for RVs and boats, backup power systems, renewable energy storage, and UPS (Uninterruptible Power Supply) systems.

Budgetary constraints should also be evaluated. Flooded batteries need periodic maintenance, including checking and topping up electrolyte levels, equalizing charges, and monitoring specific gravity (the ratio of the density of the electrolyte to the density of water). This maintenance requirement adds to the overall cost and effort of using flooded batteries. On the other hand, AGM batteries may have a higher upfront cost, but they offer convenience and durability, potentially reducing long-term costs.

Lastly, the charging control available in your system should be examined. AGM batteries may require more sophisticated charging control to prevent overcharging, while flooded batteries can tolerate higher charging voltages. We recommend our guide to charging sealed lead acid batteries.

Are AGM Batteries safer than flooded?

Flooded batteries can emit gases, including hydrogen and oxygen, during charging and discharging. Adequate ventilation is necessary to prevent the buildup of potentially hazardous gases. Additionally, the presence of liquid electrolyte in flooded batteries poses a risk of leakage and corrosion if not properly handled or maintained.

AGM batteries on the other hand, are designed with recombination capabilities, meaning they recombine the gases produced during charging. This recombination process significantly reduces the emission of hazardous gases, making AGM batteries safer to use in enclosed spaces. The sealed design of AGM batteries also eliminates the risk of electrolyte leakage and corrosion.

Conclusion

Flooded batteries and AGM batteries are two distinct types of lead acid batteries, each with its own set of advantages and considerations. Flooded batteries require regular maintenance and fluid level checks, while AGM batteries are maintenance-free. Flooded batteries can handle higher discharge rates. AGM batteries provide convenience, safety, and better resistance to vibration and shock. Understanding these differences will help you select the appropriate battery type based on your application requirements, maintenance preferences, and safety considerations.

AGM vs Flooded Batteries: What You Need to Know

Most companies use rechargeable batteries to operate their vehicles, workplace equipment, or renewable energy systems. The most commonly used is the lead acid battery. This mature technology is known to be reliable, durable, and cost-effective. However, under the lead acid battery category, there are many different types to be aware of. This article will discuss the differences between Absorbed Glass Mat (AGM) and Flooded batteries.

Absorbed Glass Mat (AGM) and wet cell or &#;flooded&#; batteries are lead batteries and contain an electrolyte solution that causes a chemical reaction and produces electrons. These batteries are recharged when put in contact with a reverse current. But, given how they are designed, they each have pros and cons, and you should consider these variations before use.

 

What is an AGM Battery

For more information, please visit maintenance free battery vs agm.

Related links:
10 Questions You Should Know about Electric Vehicle Charging Stations

Absorbed glass mat batteries, or AGM batteries, became popular in the s. They were used to power motorcycles, military, aircraft, and submarines, but now you can find them in everyday cars and trucks.

AGM batteries are a maintenance-free alternative to traditional flooded lead-acid batteries. They are designed to provide powerful bursts of starting amps and run electronics longer. 

 

How do AGM batteries work

An AGM (absorbed glass mat) battery contains a special glass mat separator that wicks the electrolyte solution between the battery plates. This material&#;s design enables the fiberglass to be saturated with electrolytes &#; and to store the electrolyte in a &#;dry&#; or suspended state rather than in free liquid form.

As the battery works, the electrolyte is transferred from the glass mat to the battery plates as required. The mat contains enough electrolyte for the battery to deliver its total capacity, and &#; should the battery case become damaged, or the battery is tipped on its side &#; its electrolyte will not spill.

 

Pros and cons of AGM batteries

Pros

These batteries are called maintenance-free batteries and do not require watering service. Since there is no free liquid and minimal gassing, AGM batteries can perform better than flooded batteries in applications where maintenance is complex.
  • Maintenance free
  • Long service life
  • High current delivery
  • Extremely low-maintenance: Does not require watering service, which lowers operating costs
  • Can perform better than flooded batteries in applications where maintenance is complex to perform
  • Can be installed sideways -- electrolyte will remain inside

These batteries are called maintenance-free batteries and do not require watering service. Since there is no free liquid and minimal gassing, AGM batteries can perform better than flooded batteries in applications where maintenance is complex.

 

Cons

Users should take care when charging this battery as over, and under-charging can affect their life and performance. AGM batteries perform most reliably when limited to discharge no more than 50% of battery capacity.

  • Take care when charging; over- and under-charging can affect life and performance
  • Limit discharge to 50% of battery capacity for the best reliability
  • Often higher up-front cost than lead-acid batteries (often 3X+ cheaper than lithium-ion, though)

AGM batteries are often found in off-grid power systems, including environmentally friendly renewable energy systems like wind and solar power. They are also great for electric vehicle service, uninterrupted power supply systems, robotics, and some ATVs and motorcycles.

 

What is a Flooded Battery

Possibly the most &#;traditional&#; type of battery, wet or flooded batteries are widely used in cars, stationary (large) uninterrupted power supplies, and of course, stand-alone energy systems. These batteries contain a combination of liquid electrolytes. The liquid in these batteries must be carefully measured and maintained to perform correctly.

 

How do Flooded batteries work

Flooded batteries use a liquid electrolyte-containing medium to trigger a chemical reaction. When the battery is connected, acid bonds to the lead plates. This causes a reaction that sends an electric current through the attached circuit. 

 

Pros and cons of Flooded batteries

Pros

Wet Cell batteries are typically the best for backup power applications, utility, and grid energy storage. Additionally, they are more cost-effective when compared to AGM batteries.

  • Extended lifespan
  • 100+ years of improvements and proven field use
  • Highest ROI and lowest operating costs (50% - 90% less expensive than other chemistries
  • Easy maintenance

 

Cons

Most of the cons of flooded batteries stem from the fact that they contain free liquid that requires periodic inspection and maintenance.  Flooded batteries can also be inadvertently damaged in forceful movement. Extreme climates can significantly affect the battery life because the electrolyte solution inside the battery can evaporate or freeze.

  • Requires periodic inspection and maintenance. 
  • It can be inadvertently damaged in forceful movement.
  • Extreme climates may have a more significant effect on battery life due to evaporation or freezing.

While flooded batteries require maintenance, if taken care of properly, this type will last longer than many of its counterparts.

 

 

With AGM and flooded batteries, following the manufacturer's instructions for charging and maintenance is essential to secure optimum performance. If you are careful about connection processes, charging, and a safe storing environment, you are taking the necessary steps to protect your battery investment.

 

Are you interested in learning more about car batteries start stop? Contact us today to secure an expert consultation!

59

0

Comments

Please Join Us to post.

0/2000

All Comments ( 0 )

Guest Posts

If you are interested in sending in a Guest Blogger Submission,welcome to write for us!

Your Name: (required)

Your Email: (required)

Subject:

Your Message: (required)